Ratio of the concentration of an adsorbate onto a solid to its partial pressure in the gas phase
The Henry adsorption constant is the constant appearing in the linear adsorption isotherm, which formally resembles Henry's law; therefore, it is also called Henry's adsorption isotherm. It is named after British chemist William Henry. This is the simplest adsorption isotherm in that the amount of the surface adsorbate is represented to be proportional to the partial pressure of the adsorptive gas:[1]

where:
- X - surface coverage,
- P - partial pressure,
- KH - Henry's adsorption constant.
For solutions, concentrations, or activities, are used instead of the partial pressures.
The linear isotherm can be used to describe the initial part of many practical isotherms. It is typically taken as valid for low surface coverages, and the adsorption energy being independent of the coverage (lack of inhomogeneities on the surface).
The Henry adsorption constant can be defined as:[2]

where:
is the number density at free phase,
is the surface number density,
Application at a permeable wall
Source:[2]
If a solid body is modeled by a constant field and the structure of the field is such that it has a penetrable core, then
![{\displaystyle K_{H}=\int \limits _{-\infty }^{x'}{\big [}\exp(-\beta u)-\exp(-\beta u_{0}){\big ]}dx-\int \limits _{x'}^{\infty }{\big [}1-\exp(-\beta u){\big ]}dx.}](https://wikimedia.org/api/rest_v1/media/math/render/svg/11ab806941cc157f4c38c07e056517987a8a5607)
Here
is the position of the dividing surface,
is the external force field, simulating a solid,
is the field value deep in the solid,
,
is the Boltzmann constant, and
is the temperature.
Introducing "the surface of zero adsorption"

where

and

we get
![{\displaystyle K_{H}(x')=[x'-x_{0}(T)][1-\exp(-\beta u_{0})]}](https://wikimedia.org/api/rest_v1/media/math/render/svg/126437361830e878dfd195a93e67869fe8c26f01)
and the problem of
determination is reduced to the calculation of
.
Taking into account that for Henry absorption constant we have

where
is the number density inside the solid, we arrive at the parametric dependence
![{\displaystyle K_{H}=\int \limits _{-\infty }^{x'}{\big [}k_{H}^{{\widetilde {u}}(x)}-k_{H}{\big ]}dx-\int \limits _{x'}^{\infty }{\big [}1-k_{H}^{{\widetilde {u}}(x)}{\big ]}dx}](https://wikimedia.org/api/rest_v1/media/math/render/svg/5d4bba5c85439e602d0e378933ac6c762427367e)
where

Application at a static membrane
Source:[2]
If a static membrane is modeled by a constant field and the structure of the field is such that it has a penetrable core and vanishes when
, then
![{\displaystyle K_{H}=\int \limits _{-\infty }^{\infty }{\big [}\exp(-\beta u)-1{\big ]}dx.}](https://wikimedia.org/api/rest_v1/media/math/render/svg/6341193133d45cdcffe8283b220fd59d5179f4c2)
We see that in this case the
sign and value depend on the potential
and temperature only.
Application at an impermeable wall
Source:[3]
If a solid body is modeled by a constant hard-core field, then
![{\displaystyle K_{H}=\int \limits _{-\infty }^{x'}\exp(-\beta u)dx-\int \limits _{x'}^{\infty }{\big [}1-\exp(-\beta u){\big ]}dx,}](https://wikimedia.org/api/rest_v1/media/math/render/svg/beac4cf68dcd57ad46f7d7268316fc16774b8648)
or

where

Here


For the hard solid potential

where
is the position of the potential discontinuity. So, in this case

Choice of the dividing surface
Sources:[2][3]
The choice of the dividing surface, strictly speaking, is arbitrary, however, it is very desirable to take into account the type of external potential
. Otherwise, these expressions are at odds with the generally accepted concepts and common sense.
First,
must lie close to the transition layer (i.e., the region where the number density varies), otherwise it would mean the attribution of the bulk properties of one of the phase to the surface.
Second. In the case of weak adsorption, for example, when the potential is close to the stepwise, it is logical to choose
close to
. (In some cases, choosing
, where
is particle radius, excluding the "dead" volume.)
In the case of pronounced adsorption it is advisable to choose
close to the right border of the transition region. In this case all particles from the transition layer will be attributed to the solid, and
is always positive. Trying to put
in this case will lead to a strong shift of
to the solid body domain, which is clearly unphysical.
Conversely, if
(fluid on the left), it is advisable to choose
lying on the left side of the transition layer. In this case the surface particles once again refer to the solid and
is back positive.
Thus, except in the case of static membrane, we can always avoid the "negative adsorption" for one-component systems.
See also
References
- ^ H. Yıldırım Erbil, "Surface Chemistry of Solid And Liquid Interfaces", Blackwell Publishing, 2006.(google books)
- ^ a b c d Zaskulnikov V. M., Statistical mechanics of fluids at a permeable wall: arXiv:1111.0082
- ^ a b Zaskulnikov V. M., Statistical mechanics of fluids at an impermeable wall: arXiv:1005.1063